-40%

220V S&A CW-FL-1000BN Industrial Water Chiller for Cooling 1000W Fiber Laser

$ 1514.76

Availability: 100 in stock
  • Reducer: Capillary
  • MPN: CW FL 1000BN
  • Machine power: 2.19KW
  • Model: CW-FL-1000BN
  • UPC: 8414830970686
  • Temperature Control: Refrigerated
  • Brand: S&A
  • Voltage: AC 1P 220V
  • Precision: ±0.5℃
  • Refrigerant: R-410a
  • Electric assisted power: 400W+600W
  • Product: Water Chiller
  • Pump power: 0.55 KW
  • Current: 3.4~10.5 A
  • Condition: New
  • Tank capacity: 15 L

    Description

    Description
    S&A CW-FL-1000AN
    industrial water chiller
    for Cooling 1000W Fiber Laser,
    With Dual Digital Temperature Controller, AC 1P 220V, 60Hz
    Stock in California, USA
    2 Years warranty, Free technical support / Free Parts replacement
    Door to Door delivery
    Accept Local pick-up
    CWFL-1000 chiller developed by S&A is made especially for fiber laser applications up to 1KW.
    It comes with dual temperature control circuit particularly suitable for separate cooling for the fiber laser and the laser head.
    No need of a two-chiller solution.
    Offering temperature stability as tight as ±0.5℃, this laser chiller unit has been engineered to keep the fiber laser system efficient and enhance its longevity.
    With consistent temperatures from laser cooling system CWFL-1000, your fiber laser system can always perform at an optimum.
    Features:
    1. Dual channel design for cooling fiber laser and the laser head, no need of a two-chiller solution;
    2. ±0.5℃ precise temperature control;
    3.
    Temperature control range: 5-35 ℃;
    4. Constant temperature and intelligent temperature control modes;
    5. Built-in alarm functions to avoid water flow problem or temperature problem;
    6.
    CE, RoHS, ISO and REACH compliant;
    7. User-friendly temperature controllers for easy operation
    8. Optional heater and water filter.
    Specification
    Specification
    Model
    CW-FL-1000BN
    Voltage
    AC 1P 220V
    Frequency
    60 Hz
    Current
    3.4~10.5 A
    Machine power
    2.19KW
    Refrigeration capacity
    14757Btu/h 4.33KW   3719Kcal/h
    Electric assisted power
    400W+600W
    Refrigerant
    R-410a
    Refrigerant charge
    900g
    Precision
    ±0.5℃
    Reducer
    Capillary
    Protection
    Overcurrent protection for compressor, flow alarm, over temperature alarm
    Pump power
    0.55 KW
    Tank capacity
    15 L
    Inlet and outlet
    Rp1/2”+Rp1/2”
    Rated flow
    2L/min+>12L/min
    N.W
    67Kgs (148lb)
    G.W
    77Kgs (170lb)
    Dimension
    700mm x 470mm x 890mm(27.6in x 18.5in x 35in)
    Package dimension
    740mm x 610mm x 1040mm(29.1in x 24in x 41in)
    The max. pump flow is obtained by testing the pump individually on test criteria GB/T 3216-2005.criteria GB/T 3216-2005.
    Note:
    1. The working current can be different under different working conditions; The above information is for reference only. Please
    subject to the actual delivered product;
    2. Clean, pure, impurity free water should be used. The ideal one could be purified water, clean distilled water, deionised water, etc.;
    3. Change out the water periodically (every 3 months is suggested or depending on the actual working environment);
    4. Location of the chiller should be well ventilated environment. There must be at least 50cm from the obstacles to the air outlet which is on the top of the chiller and should leave at least 30cm between obstacles and the air inlets which are on the side casing of the chiller.
    PRODUCT INTRODUCTION
    User-friendly temperature controllers for easy operation
    Equipped with drain port and universal wheels
    Dual inlet and dual outlet port made of stainless steel to prevent potential corrosion or water leakage
    Water level check lets you know when it’s time to refill the tank
    Cooling fan of famous brand installed, With high quality and low failure rate
    Alarm Description
    CWFL-1000 chiller is designed with built-in alarm functions.
    E1- ultrahigh room temperature
    E2 - ultrahigh water temperature
    E3 - ultralow water temperature
    E4 - room temperature sensor failure
    E5 - water temperature sensor failure
    E6 - external alarm input
    E7 - water flow alarm input
    CHILLER APPLICATION