110V -20~100℃ Low Temperature Cooling Liquid Circulator 6LIntroduction
DC series low temperature constant temperature bath is an indispensable laboratory equipment. Which is widely used in biological engineering, medicine, food, chemical industry, metallurgy, chemical analysis, oil and other fields, provide a high precision, controlled, uniform temperature constant field source for the user, is the large, medium and small research, colleges and universities, factory laboratories, quality inspection departments ideal thermostat.
Please notice:
There is a transformer involved in this item, 110V to 220V, so you can connect with power supply directly
Features
1. The machine adopts microcomputer based temperature control. High accuracy of temperature control.
2. Intelligent digital system can correct the deviation of the temperature measurement, which make the digital resolution 0.1℃.
3. The refrigeration system has over-heating and over-current multiple protective function.
4. The machine has intelligent instrument control, which easy to operate and of high temperature stability. It is also has alarm function when the temperature reach the upper and lower limitation.
5. Equipped with fully efficient anti-interference compressor.
6. Cooling rate is faster than similar products, lower noise, lower vibration.
Parameter
Model: DC-0506
Volume: 6L
Power:
800W/900W/1000W/1500W
Operating ambient temperature: 5℃-30℃
Relative maximum humidity: 80%
Temperature range:
-5℃-100℃/
-10℃-100℃/-20℃-100℃/-30-100
℃
Temperature fluctuation:
±0.1℃
Internal material: 304 stainless steel
External material:
08F
high
quality
steel
plate
Opening Size: 6''×4.3''
External dimensions: 16''×19''×33''
Circulating pump flow: 8L/min
Net weight: 45kg(99lb)
Voltage: 110V
Instruction
1. Remove the package, clean the working platform
2. Add liquid medium into tank, make the medium level 30mm(1.18'') lower than the working platform
3. Connecting circulating pump inlet and outlet pipe
①When the pump doesn't need to carry out the outer-circulation, just need to use hose to connect the inlet pipe with the outlet pipe
②When the pump is used for the outer circulation of the constant temperature liquid, please use 1 pipe to connect the outlet pipe of the pump with the inlet pipe of the container outside of the tank. Use another pipe to connect the inlet pipe of the pump with the outlet pipe of the container outside of the tank.
Precautions
1. Before using the tank, please must add liquid medium, otherwise, it will damage the heater. The medium level must lower than the platform.
2. The selection of the liquid medium in the tank shall be in accordance with the following principles:
A. When the operating temperature is
5℃-85℃
, the liquid medium usually use water
B. When the operating temperature is
85℃-95℃
, the liquid medium can use 15% glycerin-water solution
C. When the operating temperature is lower than
5℃
, the liquid medium is generally alcohol or freeing liquid
3. To improve the service life of the refrigeration system, the system adopt startup protection. Once turn off the refrigeration system, it will need 10-20minutes' space to turn on the switch again (such as turn on the switch to start the compressor in less than 10 minutes from the last operation, it is a normal phenomenon that the system will not start)
4. Power supply should be greater than the total power of the machine, the power supply must have a good grounding device.
5. The machine should be placed in a dry and ventilated place.
6. When the working temperature is very low, please do not put your hands into the tank to avoid frostbite.
7. Cut off power supply when finishing working.
Items included:
1 set of Low Temperature Cooling Machine
Item#
Description
QTY
Unit
020041/020238/020239/020134
Low Temperature Cooling Machine
1
Set
Shipping & Handling Details
On Jun-11-20 at 02:01:02 PDT, seller added the following information: